BT-610-9800 Rev A Met One Instruments, Inc 1600 Washington Blvd. Grants Pass, Oregon 97526 Telephone 541-471-7111 Facsi
BT-610 Manual Page 9 BT-610-9800 Rev A Figure 3 – BT-610 Layout Power Switch Charger Jack USB for Data Transfer (on side) RS-232
BT-610 Manual Page 10 BT-610-9800 Rev A Component Description Display 4X20 character LCD display (backlit) Keyboard 8 key membrane keypad Pri
BT-610 Manual Page 11 BT-610-9800 Rev A 6. The unit is ready for use. 3. User Interface The BT-610 user interface is composed of an 8 button
BT-610 Manual Page 12 BT-610-9800 Rev A 4.2. Printer Operation Figure 5 – Open Printer Door If there is no paper loaded in the printer,
BT-610 Manual Page 13 BT-610-9800 Rev A 4.3. Operate Screen The Operate Screen displays the date/time, sample status, current sample data and
BT-610 Manual Page 14 BT-610-9800 Rev A 4.3.2. Sampling The Operate Screen displays current sample information when the unit is sampling (real t
BT-610 Manual Page 15 BT-610-9800 Rev A 4.3.5. Warnings / Errors The BT-610 displays warning/error messages on the top line of the Operate Scre
BT-610 Manual Page 16 BT-610-9800 Rev A 4.4.6. Sample Timing The following figures depict the sample timing sequence for both manual and auto sa
BT-610 Manual Page 17 BT-610-9800 Rev A SET CLOCK Set the date and time. Set Clock Screen SET CONTRAST Adjust the display contrast. Set Con
BT-610 Manual Page 18 BT-610-9800 Rev A 5.2.4. Samples The samples setting controls the number of samples to take as illustrated below. Selec
BT-610 Manual Page 1 BT-610-9800 Rev A Copyright Notice BT-610 Manual © Copyright 2012 Met One Instruments, Inc. All Rights Reserved Worldwide
BT-610 Manual Page 19 BT-610-9800 Rev A 5.4.1. Report Type The Report setting determines the output format for the Serial Port. The choices are
BT-610 Manual Page 20 BT-610-9800 Rev A 5.6. Favorites Screen The Favorites mode eliminates the need to scroll the display when monitoring two
BT-610 Manual Page 21 BT-610-9800 Rev A 5.7. Calibrate Flow Screen The BT-610 has a factory calibrated flow rate of 0.1 CFM (2.83 LPM). Under
BT-610 Manual Page 22 BT-610-9800 Rev A 5.9. Set Clock Screen To set the date and time select SET CLOCK from the menu. Figure 22 shows the Set
BT-610 Manual Page 23 BT-610-9800 Rev A COPY TO USB DRIVE RECALL DATA PRINT DATA MEMORY Figure 25 – Data Screen 6.1. Copy to USB Dri
BT-610 Manual Page 24 BT-610-9800 Rev A 6.3. Printing Sample Data Stored sample events can be printed via the serial port within a user select
BT-610 Manual Page 25 BT-610-9800 Rev A 6.4. Memory Screen The BT-610 memory is composed of a single file which contains the data from sample e
BT-610 Manual Page 26 BT-610-9800 Rev A attached. Charge the battery before storing the BT-610. Storing a discharged battery will degrade its
BT-610 Manual Page 27 BT-610-9800 Rev A 8.1.2. User Mode User Mode is intended for direct user interaction. In User Mode, all incoming characte
BT-610 Manual Page 28 BT-610-9800 Rev A 8.2. Real Time Output The real time output occurs when the unit finishes a sample. The output format i
BT-610 Manual Page 2 BT-610-9800 Rev A Table of Contents 1. Introduction ...
BT-610 Manual Page 29 BT-610-9800 Rev A 8.3. Comma Separated Value (CSV) The CSV output fields are both comma separated and fixed length. CSV
BT-610 Manual Page 30 BT-610-9800 Rev A Status Bits Notes (for table above): Bit Value Condition 0 OK (no alarms/errors) 1. CSV header in
BT-610 Manual Page 31 BT-610-9800 Rev A Figure 32 – RS485 Connector Figure 33 – RS485 Network 9. Maintenance Due to the nat
BT-610 Manual Page 32 BT-610-9800 Rev A 9.1.1. Zero Count Test Air leaks or debris in the particle sensor can cause false counts which may resu
BT-610 Manual Page 33 BT-610-9800 Rev A 10. Troubleshooting The following section covers some common failure symptoms, causes and solutions.
BT-610 Manual Page 34 BT-610-9800 Rev A 11. Specifications Performance Particle Size Range 0.3µm - 10µm, 6 channels Calibrated Sizes 0.3 µm
BT-610 Manual Page 35 BT-610-9800 Rev A 12. Warranty / Service Warranty The BT-610 is warranted against defects and workmanship for a perio
BT-610 Manual Page 3 BT-610-9800 Rev A 5.6.4. Favorites Analog Output Scaling (A-SCALE) ...
BT-610 Manual Page 4 BT-610-9800 Rev A 1. Introduction The BT-610 is a portable airborne particle counter with a small stable footprint. This a
BT-610 Manual Page 5 BT-610-9800 Rev A
BT-610 Manual Page 6 BT-610-9800 Rev A BT-610 Battery Charger MOI P/N: 80643 Iso-Kinetic Inlet
BT-610 Manual Page 7 BT-610-9800 Rev A Figure 1 – Standard Equipment Figure 2 – Optional Equipment BT-610 Optional Equipment Temperature &
BT-610 Manual Page 8 BT-610-9800 Rev A 2.2. Layout Figure 3 shows the layout of the BT-610 and the following table provides a description of th