BT Versatility User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 59
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
BT Versatility
Installation and Maintenance Manual
23
Connecting the Battery
Ensure the battery switch on the BBU unit is turned off.
This switch does not turn off the mains supply. The mains is disconnected
by unplugging the mains cord
Insert the battery into the battery cavity in the CCU
Connect the cables from the battery charger to the battery ensuring that the cables are connected
correctly. Red cable to Red battery terminal, black cable to Black battery terminal
Turn the battery charger switch on.
Reconnect the mains.
Led Indicators
A status LED on the BBU is provided.
GREEN indicates the unit is running from mains power and the battery is charging or fully charged.
ORANGE indicates the unit is running off the Battery
RED indicates that the battery is discharged
Flashing RED indicates the battery is disconnected and the switch is running from the mains
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 58 59

Comments to this Manuals

No comments