Ofces WorldwideThe telecommunications services described in this publication are subject to availability and may be modied from time to time.Service
BT Versatility Installation and Maintenance Manual 9 Mounting the CCU The CCU is mounted on the bracket by sliding it on from the left hand side. T
BT Versatility Installation and maintenance Manual 10 Modules located in the CCU There are a number of modules that can be installed in the CCU.
BT Versatility Installation and Maintenance Manual 11System Expansion To equip the switch with more than 8 extensions or to add an Internet or Optio
BT Versatility Installation and maintenance Manual 12Mounting the Backplane Slide the backplane on from the right hand side. Ensure the connector
BT Versatility Installation and Maintenance Manual 13Expansion Modules There are three types of expansion module that can be installed on the back
BT Versatility Installation and maintenance Manual 14Installing an Expansion module Install the Backplane as described on page 12. Install the M
BT Versatility Installation and Maintenance Manual 15 Analogue line module The Analogue Line module contains circuitry for 2 Analogue Lines. The mod
BT Versatility Installation and maintenance Manual 16 To Locate the Analogue Module in the Ports Module: Remove the Ports Module by firstly openin
BT Versatility Installation and Maintenance Manual 17Digital Line Module (ISDN 2) Basic Rate ISDN expansion module The ISDN Basic Rate Module provid
BT Versatility Installation and maintenance Manual 18 To Locate the Digital Line Module (ISDN 2) in the PORTS module Remove the Ports Module by fi
BT Versatility Installation and maintenance Manual 1Contents Introduction 2 General overview 2 Safety Precautions during installation and s
BT Versatility Installation and Maintenance Manual 19System ISDN settings The system can be configured with 8 Basic Rate ISDN interfaces. Half of th
BT Versatility Installation and maintenance Manual 20Voicemail module The Voice module is coloured BLUE It is located in the Voice Module slot in
BT Versatility Installation and Maintenance Manual 21Primary Rate Interface (Availability TBC) The Primary rate ISDN Module (30B+D) is coloured Yell
BT Versatility Installation and maintenance Manual 22Connecting the battery backup unit to the system The Battery back up provides operation of an
BT Versatility Installation and Maintenance Manual 23 Connecting the Battery Ensure the battery switch on the BBU unit is turned off. • This switc
BT Versatility Installation and maintenance Manual 24 Featurephone V16 V16 Featurephone connections (underside of phone)
BT Versatility Installation and Maintenance Manual 25 Featurephone V8 V8 Featurephone connections (underside of phone) Handset conn
BT Versatility Installation and maintenance Manual 26 Attaching the Featurephone desk plinth (V8 and V16) Position at 35 degrees Positio
BT Versatility Installation and Maintenance Manual 27V16 expansion console The V16 featurephone can be equipped with a 32 key module. This provides
BT Versatility Installation and maintenance Manual 28 Clip, Plinth and installation of the V16 expansion console NOTE: For the 20 degrees p
BT Versatility Installation and maintenance Manual 2Introduction This document describes the practices to be adopted by field engineers during ins
BT Versatility Installation and Maintenance Manual 29 Wall-mounting a Featurephone The phone plinth is inverted on the base to wall mount the phone
BT Versatility Installation and maintenance Manual 30 Door Intercom The door intercom is connected to extension 23, the fourth ex
BT Versatility Installation and Maintenance Manual 31Cabling the unit All Line and Extension circuit cabling is inserted from the top of the unit. T
BT Versatility Installation and maintenance Manual 32Four wires per Extension are connected at the Main Equipment. Spare wires must be neatly lai
BT Versatility Installation and Maintenance Manual 33CCU connections The CCU has the following connectors:- • Eight four way Krone connectors for t
BT Versatility Installation and maintenance Manual 34• The MOH Module may be used with all Systems provided they are running above software versi
BT Versatility Installation and Maintenance Manual 35• Two 2 pole switches are also provided for the 100 ohm terminating resistance for the ISDN Ba
BT Versatility Installation and maintenance Manual 36Options Module MDF Connections The options module is equipped with a stereo jack for an ‘exte
BT Versatility Installation and Maintenance Manual 37Expanding an Existing system Modules may be removed and re-inserted in a system without disconn
BT Versatility Installation and maintenance Manual 38Maintenance procedures Faults can be rectified on site by replacing faulty modules or PCBs H
BT Versatility Installation and Maintenance Manual 3Safety Precautions during installation and system upgrades Always unplug or isolate the mains s
BT Versatility Installation and Maintenance Manual 39Replacing a faulty Module MDF To replace a faulty MDF of a Ports, Internet or Options module th
BT Versatility Installation and maintenance Manual 40 Replacing Faulty PCBs Replacing the 008 extension board If a fault occurs on the first eigh
BT Versatility Installation and Maintenance Manual 41 Replacing the CCU Control PCB This PCB is NOT hot swappable. The System must be powered down t
BT Versatility Installation and maintenance Manual 42 Power supply unit spare fuse A spare mains fuse is located in the Power supply unit. It is i
BT Versatility Installation and Maintenance Manual 43Replacing the Power Supply Unit The procedure to be used when replacing the Power Supply unit i
BT Versatility Installation and maintenance Manual 44Replacing the CCU MDF This PCB is NOT hot swappable. The System must be powered down to chang
BT Versatility Installation and Maintenance Manual 45Power fail When planning the extension wiring for the system, consideration should be given to
BT Versatility Installation and maintenance Manual 46Power up and test • Ensure the mains plug is fitted with a 3A fuse. Switch on • Power up th
BT Versatility Installation and Maintenance Manual 47Programming Essential programming is carried out either from a Featurephone connected to exten
BT Versatility Installation and maintenance Manual 48Call Barring Extensions are entered into different Classes for barring purposes. There are 6
BT Versatility Installation and maintenance Manual 4 BT Versatility - Packages, Spares and Maintenance Items BT Code BT Versatility Pro. P
BT Versatility Installation and Maintenance Manual 49Internet Module Programming The Internet Module can only be programmed from the BT Versatility
BT Versatility Installation and maintenance Manual 50• The following screen is displayed • If an ADSL line is connected to the Internet module
BT Versatility Installation and Maintenance Manual 51• Enter the Username. This will be provided by the ISP. • Enter the Password. This will be pr
BT Versatility Installation and maintenance Manual 52Recommendations for customer training As part of the installation, the customer is entitled t
BT Versatility Installation and Maintenance Manual 53Troubleshooting All faults can normally be traced quite readily to a particular PCB. Prior to r
BT Versatility Installation and maintenance Manual 54Technical specification Type of system Hybrid/PBX ISDN 2 line Max 4 ISDN (2B+D) Basic Rate
BT Versatility Installation and Maintenance Manual 55External Music on hold Stereo jack connector (on Options Module) Input impedance 10k ohm Nomin
BT Versatility Installation and maintenance Manual 56ISDN Access to B-channels on PABX PPP, MLPPP, BACP Protocols IP V4 Authentication PAP/CHAP D
BT Versatility Installation and Maintenance Manual 57INDEX 20 degrees, 27 35 degrees, 27 additional modules, 38 ADSL, 7, 36, 50, 51 Analogue, 46 A
Ofces WorldwideThe telecommunications services described in this publication are subject to availability and may be modied from time to time.Service
BT Versatility Installation and Maintenance Manual 5BT Versatility 8 Port Extension Module VDS 007225 BT Versatility Hospitality Application VDS
BT Versatility Installation and maintenance Manual 6BT Versatility Options MDF MTC 007261 BT Versatility Mod Retentn Long 1/4 turn Screw MTC 00
BT Versatility Installation and Maintenance Manual 7Installing the Central Control Unit CCU Location(CCU) The CCU is intended for installation in a
BT Versatility Installation and maintenance Manual 8 CCU Mounting bracket clearances The main unit is mounted on a wall using the bracket supplied